Part No. Conduit Size O.D. Size Ga. (Thickness) Finish Product Weight / Piece (lbs)
P1425 3/8″ (10) 0.577″ (14.7) 16 (1.5) EG 0.09
P1425 3/8″ (10) 0.577″ (14.7) 16 (1.5) SS 0.09
P1425AS 3/8″ (10) 0.577″ (14.7) 16 (1.5) EG 0.09
P1425AS 3/8″ (10) 0.577″ (14.7) 16 (1.5) ZD 0.09
P1426 1/2″ (13) 0.706″ (17.9) 16 (1.5) EG 0.11
P1426 1/2″ (13) 0.706″ (17.9) 16 (1.5) HG 0.22
P1426 1/2″ (13) 0.706″ (17.9) 16 (1.5) ZD 0.11
P1426 1/2″ (13) 0.706″ (17.9) 16 (1.5) SS 0.11
P1426 1/2″ (13) 0.706″ (17.9) 16 (1.5) AL 0.037
P1426AS 1/2″ (13) 0.706″ (17.9) 16 (1.5) EG 0.11
P1426AS 1/2″ (13) 0.706″ (17.9) 16 (1.5) ZD 0.11
P1427 3/4″ (19) 0.922″ (23.4) 16 (1.5) EG 0.12
P1427 3/4″ (19) 0.922″ (23.4) 16 (1.5) HG 0.13
P1427 3/4″ (19) 0.922″ (23.4) 16 (1.5) ZD 0.12
P1427 3/4″ (19) 0.922″ (23.4) 16 (1.5) SS 0.12
P1427 3/4″ (19) 0.922″ (23.4) 16 (1.5) AL 0.04
P1427AS 3/4″ (19) 0.922″ (23.4) 16 (1.5) EG 0.12
P1427AS 3/4″ (19) 0.922″ (23.4) 16 (1.5) ZD 0.12
P1428 1″ (25) 1.163″ (29.5) 14 (1.9) EG 0.15
P1428 1″ (25) 1.163″ (29.5) 14 (1.9) DF 0.16
P1428 1″ (25) 1.163″ (29.5) 14 (1.9) HG 0.16
P1428 1″ (25) 1.163″ (29.5) 14 (1.9) ZD 0.15
P1428 1″ (25) 1.163″ (29.5) 14 (1.9) SS 0.15
P1428 1″ (25) 1.163″ (29.5) 14 (1.9) AL 0.05
P1428AS 1″ (25) 1.163″ (29.5) 14 (1.9) EG 0.15
P1428AS 1″ (25) 1.163″ (29.5) 14 (1.9) ZD 0.15
P1429 1-1/4″ (32) 1.510″ (38.4) 14 (1.9) EG 0.18
P1429 1-1/4″ (32) 1.510″ (38.4) 14 (1.9) DF 0.18
P1429 1-1/4″ (32) 1.510″ (38.4) 14 (1.9) ZD 0.7
P1429 1-1/4″ (32) 1.510″ (38.4) 14 (1.9) SS 0.18
P1429 1-1/4″ (32) 1.510″ (38.4) 14 (1.9) AL 0.06
P1429AS 1-1/4″ (32) 1.510″ (38.4) 14 (1.9) EG 0.18
P1429AS 1-1/4″ (32) 1.510″ (38.4) 14 (1.9) ZD 0.18
P1430 1-1/2″ (38) 1.740″ (44.2) 12 (2.7) EG 0.29
P1430 1-1/2″ (38) 1.740″ (44.2) 12 (2.7) DF 0.29
P1430 1-1/2″ (38) 1.740″ (44.2) 12 (2.7) ZD 0.71
P1430 1-1/2″ (38) 1.740″ (44.2) 12 (2.7) SS 0.29
P1430AS 1-1/2″ (38) 1.740″ (44.2) 12 (2.7) EG 0.29
P1430AS 1-1/2″ (38) 1.740″ (44.2) 12 (2.7) ZD 0.29
P1431 2″ (51) 2.197″ (55.8) 12 (2.7) EG 0.33
P1431 2″ (51) 2.197″ (55.8) 12 (2.7) DF 0.35
P1431 2″ (51) 2.197″ (55.8) 12 (2.7) HG 0.35
P1431 2″ (51) 2.197″ (55.8) 12 (2.7) ZD 0.33
P1431 2″ (51) 2.197″ (55.8) 12 (2.7) SS 0.33
P1431 2″ (51) 2.197″ (55.8) 12 (2.7) AL 0.11
P1431AS 2″ (51) 2.197″ (55.8) 12 (2.7) EG 0.33
P1431AS 2″ (51) 2.197″ (55.8) 12 (2.7) ZD 0.33

Note: When tightening 1/4″ screws used with a two piece pipe clamp, a torque of 5 ft-lbs (60 in-lbs) should be used.

Material:

  • The steel meets or exceeds the physical properties of ASTM A1011 GR 33, except with SS, ST & AL finishes.

Finishes:

  • Electrogalvanized (EG):  Conforms to ASTM B633, Type III SC1
  • Unistrut Defender (DF):  Conforms to ASTM A1059
  • Hot Dip Galvanized (HG):  Conforms to ASTM A123 or A153
  • Perma-Gold (ZD):  Conforms to ASTM B633, Type II SC1 or SC3
  • Everdur (E EG): TBD
  • Stainless Steel, Type 304 (SS):  ASTM A240, Type 304 *
  • Stainless Steel, Type 316 (ST):  ASTM A240, Type 316 *
  • Aluminum (AL): TBD

* These materials have different physical properties and performance characteristics. Please contact us for design support.

 

Material / Finish
Part Number
Suffix
Pipe Clamp
Material / Finish
Fasteners (Screw & Nut)
Material / Finish
Example
Electro-galvanized
EG
EG
EG
P1109 EG
Hot-dipped galvanized
HG
HG
SS
P1109 HG
Unistrut Defender
DF
DF
DF
P1109 DF
Stainless Steel Type 304
SS
SS
SS
P1109 SS
Stainless Steel Type 316
ST
ST
SS
P1109 ST
Aluminum
AL
AL
AL
P1109 AL
Copper Coated
CC
CC
CC
P1109 CC
Everdur
E EG
EG
E
P1109E EG
P1425 Thru P1431
Part Number Conduit Size Design Load
(lbs)
P1425 3/8″ 400
P1426 1/2″ 400
P1427 3/4″ 400
P1428 1″ 600
P1429 1-1/4″ 600
P1430 1-1/2″ 800
P1431 2″ 800
P1118 2-1/2″ 800
P1119 3″ 800
P1120 3-1/2″ 1,000
P1121 4″ 1,000

Notes:

Design loads apply only to Unistrut brand products. Look for “UNISTRUT” on the part.

For use with non-seismic loads. Based on static testing in 12 ga. channel with a safety factor of 5.0.

For use with seismic loads supporting Schdule EMT or IMC Conduit. Based on FM1950-10 dynamic testing in 12 ga. channel with a safety factor of 1.5. For conduit sizes larger than 2″, see the P1109 thru P1126 series clamps.