Strut Services Group, Inc.

Unistrut Alabama

P3352-P3353

SKU P3352-P3353 Categories ,
$

P3352 thru P3353 – Concrete insert (8 in – 12 in)

Part No. Length (ft) Finish Product Weight / Piece (lbs)
P3352NC 8″ (203) PG 1.22
P3352NC 8″ (203) PL 1.22
P3352WC 8″ (203) PG 1.22
P3352WC 8″ (203) PL 1.22
P3353NC 12″ (305) PG 1.74
P3353WC 12″ (305) PG 1.74
P3353WC 12″ (305) PL 1.74

Specifications:

  • Includes closure and end caps unless otherwise requested.
  • P3380 end cap used with distance to first anchor is up to 2″ (51 mm).
  • P3703 end cap is used when end distance to first anchor is over 2″ (51 mm).
  • Nail or anchor inserts to forms every 16″ (406.4 mm) to 24″ (609.6 mm).
  • Anchors are 8″ (203.3 mm) on center.

Options:

  • “NC” Suffix – No Closure Strip, with End Caps & Back Plates
  • “WC” Suffix – With Closure Strip, End Caps & Back Plates
  • “X” Suffix – No Closure Strip, no End Caps, with Back Plates

Materials & Finishes – Standard:

  • Pregalvanized (PG):  Conforms to ASTM A653 SS GR 33, G90.
  • Unistrut Defender (DF):  Conforms to ASTM A1046 SS GR 33
  • Hot Dip Galvanized (HG):  Steel conforms to ASTM A1011 SS GR 33, Finish conforms to ASTM A123
  • Perma-Green (GR):  Steel conforms to ASTM A1011 SS GR 33, E-Coat finish
  • Perma-Gold (ZD):  Steel conforms to ASTM A1011 SS GR 33, Finish conforms to ASTM B633, Type II SC3
  • Plain (PL):  Conforms to ASTM A1011 SS GR 33

Materials & Finishes – Special Metals:

  • Stainless Steel, Type 304 (SS):  ASTM A240, Type 304 *
  • Stainless Steel, Type 316 (ST):  ASTM A240, Type 316 *
  • Aluminum (EA):  ASTM B221, Type 6063-T6 (Extruded) *

* These materials have different physical properties and performance characteristics. Please contact us for design support.

Part Number Insert Length
in or ft (mm)
Max. Allowable Point Load
lbs (kN)
Min. Spacing of Point Loads
in (mm)
Max. Allowable Uniform Load
lbs (kN)
 Max. Allowable Uniform Load
lbs/ft (kg/m)
P3352 8″  (203.2) 1,000  (4.45) 1,000  (4.45)
P3353 12″  (304.8) 1,500  (6.67) 1,500  (6.67)

Notes:

Design loads are based on 3,000 PSI concrete, unless noted otherwise.
Safety Factor = 3.0

Scroll to Top